Lightweight CRP Test Kit 5-15 Mins Testing Time 10 μG/Ml Cutoff Rapid Diagnostic

Lightweight CRP Test Kit 5-15 Mins Testing Time 10 μG/Ml Cutoff Rapid Diagnostic

MOQ:5000pcs
PRODUCT DESCRIPTION
High Light:

heart disease blood test

,

heart related blood tests

Brand Name New Life
Certification ISO13485,CE
Delivery Time 20-30days
Minimum Order Quantity 5000pcs
View More
ABOUT US
Orient New Life Medical Co.,Ltd.
Orient New Life Medical Co.,Ltd. manufacturer profile
12F,Guting Building,Hefeng Creative Square,No.495 Jiangdong North Road,Ningbo,Zhejiang, China ,China
5.0
Verified Supplier
View More
Get the Best Price for
Lightweight CRP Test Kit 5-15 Mins Testing Time 10 μG/Ml Cutoff Rapid Diagnostic
Lightweight CRP Test Kit 5-15 Mins Testing Time 10 μG/Ml Cutoff Rapid Diagnostic
MOQ: 5000pcs
Continue
Recommended Products
About Us
Orient New Life Medical Co.,Ltd.
Orient New Life Medical Co.,Ltd. manufacturer profile
12F,Guting Building,Hefeng Creative Square,No.495 Jiangdong North Road,Ningbo,Zhejiang, China ,China
5.0
Verified Supplier
Company Name Orient New Life Medical Co.,Ltd.
Business Type: Manufacturer,Exporter
Brands: New Life
No. of Employees: 200~300
Year Established: 2009
Annual Sales: 10,000,000-15,000,000
Company Location 12F,Guting Building,Hefeng Creative Square,No.495 Jiangdong North Road,Ningbo,Zhejiang, China
Factory Location No.1369, Chengnan Road, Jiaxing, Zhejiang, China
China Orient New Life Medical Co.,Ltd. manufacturer profile
China Orient New Life Medical Co.,Ltd. manufacturer profile
China Orient New Life Medical Co.,Ltd. manufacturer profile

Established in 2009, Orient New Life Medical Co., Ltd., is specialized in high-tech biological diagnostic test development, research and production, as well as high-tech medical device development, research and production. New Life has built up two production base, which produce biological diagnostic test and endoscopic medical device respectively. Our products ranged in the following specialties: drug of abuse tests, fertility tests, infectious diseases tests, sexual transmitted diseases tests, tumor markers tests, cardiac markers tests, veterinary tests, and surgical stapler series.

 

NEW LIFE have 3 wholly-owned and joint stock subsidiary companies, including Orient New Life Medical  Co., Ltd., Orient Gene Biotech Co., Ltd., Qianjing Medical Equipment Co., Ltd.

 

Company's core technical team with more than 35 employees,3 doctors and 25 masters. They have many years of famous universities in the United States and pharmaceutical companies engaged in the project research and development, production and marketing, business management experience.Company owns hundreds of grade purification workshop and all level of quality checkout room, equipped with various production and testing equipment.

Get Latest Price For Your Requirement
PRODUCT DESCRIPTION
High Light:

heart disease blood test

,

heart related blood tests

Place of Origin China
Brand Name New Life
Certification ISO13485,CE
Model Number cassette
Minimum Order Quantity 5000pcs
Packaging Details 1pc/pouch, 25pcs/box
Delivery Time 20-30days
Payment Terms T/T, Western Union, MoneyGram
Supply Ability 2000000pcs/month
Category Cardiac
Format Strip/cassette
Specimen Whole Blood/Serum/Plasma
Testing time 5-15 minutes
Shelf Life 24 Months
Application CRP
Accuracy 98.7%

 

Lightweight CRP Test Kit 5-15 Mins Testing Time 10 μG/Ml Cutoff Rapid Diagnostic

Description:

quickly and easily CRP Rapid Diagnostic Test, diagnosis of myocardial infarction (MI), gold colloidal method

 

 

Product Cat No Specimen Sensitivity Format Kit Size
CrP (C-reactive protein ) YC105C4 WB / S / P See Insert 4mm Cassette 25T

 

 

 

Intended Use:

 

 

The CRP Rapid Test Cassette (Whole Blood/Serum/Plasma) is a rapid chromatographic immunoassay for the qualitative detection of human CrP in whole blood, serum or plasma as an aid in the diagnosis of myocardial infarction (MI). The cutoff of the test is 10 μg/ml.

 

Summary:

 

C-reactive Protein (CrP) in patient’s sera has been found in association with acute infections, necrotic conditions and a variety of inflammatory disorders. There is a strong correlation between serum levels of CrP and the onset of the inflammatory process. Monitoring the levels of CrP in patient’s sera indicates the effectiveness of treatment and the assessment of patient recovery. It is used in particular to differentiate bacterial infections from virus infections

 

Test Principle:

 

 

The CrP Rapid Test Cassette (Whole Blood/Serum/Plasma) detects C-reactive Protein through visual interpretation of color development on the internal cassette. The sample now moves through the test cassette from bottom to top. If the test sample contains CrP, it attaches to the anti-CrP antibody which is conjugated with a red gold colloidal for color marking. The more CrP is contained in the sample, the more red lines become visible. A red line should always appear in the control (C) line area. It serves as a procedural control, confirming that sufficient specimen volume was used and indicates an adequate membrane wicking and proper procedural technique.

 

TEST PROCEDURE

 

1.  Bring the pouched test device to room temperature(15-30℃) prior to testing. Do not

open the pouch until ready to begin testing.

 

2.  Remove the device from the sealed pouch and lay it on a flat and dry surface.

 

3.  Open the tube with the diluted sample .Transfer 3 drops of mixed specimens to sample well. Start the timer.

 

4.  Wait for the colored lines to appear. The result should be read at 5 minutes. Do not interpret the results at 10 minutes.

 

 

INTERPRETATION OF RESULTS

 

 

POSITIVE:* Two lines appear. One colored line should be in the control line region (C) and another apparent colored line should be in the test line region (T).

 

*NOTE: The intensity of the color in the test line region (T) will vary depending on the concentration of TP antibodies present in the specimen. Therefore, any shade of color in the test line region (T) should be considered positive.

 

 

NEGATIVE: One colored line appears in the control line region (C). No line appears in the test line region (T).

 

INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit immediately and contact your local distributor.

 

 

 [#varpname#] 0

 

 
ORIENT NEW LIFE MEDICAL CO., LTD.
Contact: Jerry Meng
Email: Jerry @ newlifebiotest .com
Tel. +86 18657312116
SKYPE enetjerry
Get Latest Price For Your Requirement